Standard Stall Sizes
| Stall Type | Width | Depth | Door Width |
|---|---|---|---|
| Standard adult | 36" | 60" | 24" |
| Wider adult / juvenile | 30" | 60" | 22" |
| ADA accessible | 60" | 56–59" | 32" min clear |
| Ambulatory accessible | 36" | 60" | 32" min clear |
Partition Heights & Floor Clearances
| Standard panel height | 58" |
| Standard floor gap | 12" |
| Standard pilaster height | 82" |
| Floor-to-ceiling pilaster | Custom (matches ceiling) |
| Privacy panel option | 72–84" with 4–6" floor gap |
How to Measure Your Restroom
- Measure the back wall length where pilasters and panels will mount.
- Measure the depth from back wall to the front of the stall.
- Identify the ADA stall location — minimum 60" wide, accessible from the entry approach.
- Confirm the door swing direction (outswing required for ADA).
- Verify ceiling height if you're considering overhead-braced or ceiling-hung mounting.
- Photograph the wall and floor conditions and send them with your quote request.
For detailed accessibility requirements, see our ADA compliance guide. When you're ready, request a quote with your measurements.